{"id":2149,"date":"2020-06-10T16:14:10","date_gmt":"2020-06-10T07:14:10","guid":{"rendered":"https:\/\/www.shi-ftec.co.jp\/en\/en\/?page_id=2149"},"modified":"2020-06-10T16:14:23","modified_gmt":"2020-06-10T07:14:23","slug":"detail1","status":"publish","type":"page","link":"https:\/\/www.shi-ftec.co.jp\/en\/services\/detail1\/","title":{"rendered":"Proposals for preventive maintenance: CNC Precision Surface Grinding Machine &#8211; KSH Series"},"content":{"rendered":"<div class=\"wrapper\">\r\n    <div class=\"container\">\r\n        <h1>Proposals for preventive maintenance: CNC Precision Surface\r\n            Grinding Machine &#8211; KSH Series<\/h1>\r\n\r\n\r\n        <h3>Self-diagnosis: Precision Surface Grinding Machine KSH Series self-diagnosis menu<\/h3>\r\n        <p>Every part of the machine is a consumable, so it may degrade and be damaged. Using the\r\n            machine under such circumstances may cause it to break down.<\/p>\r\n        <p>To prevent machine breakdowns, use the self-diagnosis menu to determine if it is necessary to\r\n            replace or repair parts.<\/p>\r\n        <p><strong>Inspection items<\/strong><\/p>\r\n        <ol>\r\n            <li>Spindle<\/li>\r\n            <li>Hydrostatic bearing spindle<\/li>\r\n            <li>Bed bellows<\/li>\r\n            <li>Column bed bellows<\/li>\r\n            <li>Linear guides<\/li>\r\n            <li>Table drive unit<\/li>\r\n        <\/ol>\r\n        <div class=\"text-center\">\r\n            <a href=\"https:\/\/www.shi-ftec.co.jp\/en\/wp-content\/uploads\/2018\/09\/service_img3.png\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\"\r\n                    src=\"https:\/\/www.shi-ftec.co.jp\/en\/wp-content\/uploads\/2018\/09\/service_img3.png\" alt=\"\" width=\"838\" height=\"822\"\r\n                    class=\"aligncenter size-full wp-image-1327\" \/><\/a>\r\n        <\/div>\r\n        <p>If any of the following applies, a machine overhaul may be necessary.<br \/>\r\n            First, please check each of the following items.<\/p>\r\n        <p>\u2460Spindle<\/p>\r\n        <ol>\r\n            <li>The operation time has exceeded 10,000 hours.<\/li>\r\n            <li>There is a strange noise when the spindle is rotating.<\/li>\r\n            <li>It feels strange when it is rotated manually.<\/li>\r\n        <\/ol>\r\n\r\n        <p>\u2461Hydrostatic bearing spindle<\/p>\r\n        <ol>\r\n            <li>20% or more of the pocket pressure is down compared to the start.<\/li>\r\n            <li>The filter is clogged.<\/li>\r\n            <li>There is abnormal heat generated.<\/li>\r\n            <li>There is a strange noise when the Hydrostatic\u3000bearing spindle is rotating.<\/li>\r\n            <li>It feels strange when it is rotated manually under hydrostatic pressure. <\/li>\r\n            <li>The oil is dirty.<\/li>\r\n        <\/ol>\r\n\r\n        <p>\u2462Bed bellows (left and right)<\/p>\r\n        <ol>\r\n            <li>There is significant degradation.<\/li>\r\n            <li>There is damage such as holes.<\/li>\r\n            <li>It is bent.<\/li>\r\n        <\/ol>\r\n\r\n        <p>\u2463Column bed bellows (front and back)<\/p>\r\n        <ol>\r\n            <li>There is significant degradation.<\/li>\r\n            <li>There is damage such as holes.<\/li>\r\n            <li>It is bent.<\/li>\r\n        <\/ol>\r\n        <p>The bellows is a consumable, so it may degrade and be damaged when used for a long period of\r\n            time.<br \/>\r\n            Using the machine under such circumstances may cause coolant, waste, etc., to enter the bed\r\n            groove and cause the machine to break down.<\/p>\r\n        <div class=\"text-center\">\r\n            <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.shi-ftec.co.jp\/en\/wp-content\/uploads\/2018\/09\/service_img4.jpg\" alt=\"\" width=\"639\" height=\"221\"\r\n                class=\"aligncenter size-full wp-image-1328\" \/>\r\n            <p>Reference: Degraded\/Bent\/Damaged bellows<\/p>\r\n        <\/div>\r\n\r\n        <p>\u2464Linear guides<\/p>\r\n        <ol>\r\n            <li>It feels strange when moving the table.<\/li>\r\n            <li>Lubricating oil has not been applied to the linear guides. (No lubricating oil on the\r\n                linear guides rail.)<\/li>\r\n            <li>Rust has developed.<\/li>\r\n        <\/ol>\r\n        <p>The Linear guides for guiding tables is hidden by the bellows, so it is not visible\r\n            usually.<br \/>\r\n            As a result, operators may not notice any damage, which may lead to a major machine failure.\r\n        <\/p>\r\n        <div class=\"row text-center\">\r\n            <div class=\"col-sm-6\">\r\n                <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.shi-ftec.co.jp\/en\/wp-content\/uploads\/2018\/09\/service_img5-1.jpg\" alt=\"\" width=\"402\" height=\"296\"\r\n                    class=\"aligncenter size-full wp-image-1329\" \/>\r\n            <\/div>\r\n            <div class=\"col-sm-6\">\r\n                <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.shi-ftec.co.jp\/en\/wp-content\/uploads\/2018\/09\/service_img5-2.jpg\" alt=\"\" width=\"255\" height=\"191\"\r\n                    class=\"aligncenter size-full wp-image-1330\" \/>\r\n            <\/div>\r\n        <\/div>\r\n        <p class=\"text-center\">Reference: Scratched\/Degraded Linear guidesrail<\/p>\r\n\r\n        <p>\u2465Table drive unit<\/p>\r\n        <ol>\r\n            <li>There is a loud noise when it is reversed (sound of metal banging).<\/li>\r\n            <li>There is a loud noise from the Speed reducer when the machine is running.<\/li>\r\n            <li>The timing belt is undulated greatly when it is reversed.<\/li>\r\n        <\/ol>\r\n        <p>Please contact us if any of the above applies.<\/p>\r\n\r\n        <h3>Updating control devices that cannot be repaired<\/h3>\r\n        <p>Some control devices installed in our grinding machines cannot be repaired after the\r\n            production has stopped and the applicable service period has passed, even if they are\r\n            broken. If a part of the device breaks down, the entire device needs to be replaced.\r\n        <\/p>\r\n        <p>Some devices may take a while to prepare, so there is a risk that they may need to be stopped\r\n            for a long period of time after they break down. As preventive maintenance, we recommend\r\n            updating control devices before that happens.<\/p>\r\n        <p>The list below is an example of such devices. We can offer solutions individually if you have\r\n            questions or requests.<\/p>\r\n        <h4>List of control devices that cannot be repaired<\/h4>\r\n        <div class=\"table-responsive\">\r\n            <table class=\"table table-bordered\">\r\n                <thead>\r\n                    <tr>\r\n                        <th>Model<\/th>\r\n                        <th>Uses<\/th>\r\n                        <th>Name<\/th>\r\n                        <th>Model<\/th>\r\n                        <th>Manufacturer<\/th>\r\n                    <\/tr>\r\n                <\/thead>\r\n                <tbody>\r\n                    <tr>\r\n                        <td rowspan=\"6\">KSH<\/td>\r\n                        <td rowspan=\"2\">Control device for spindle drive<\/td>\r\n                        <td rowspan=\"2\">Inverter<\/td>\r\n                        <td>FREQROL-A200(E)<\/td>\r\n                        <td rowspan=\"2\">Mitsubishi Electric<\/td>\r\n                    <\/tr>\r\n                    <tr>\r\n                        <td>FREQROL-Z200<\/td>\r\n                    <\/tr>\r\n                    <tr>\r\n                        <td rowspan=\"4\">Control device for magnetic chucks<\/td>\r\n                        <td rowspan=\"4\">Contourator<\/td>\r\n                        <td>NS2-5FE\u3001NS2-10FET<\/td>\r\n                        <td rowspan=\"4\">Fuji Jikoh<\/td>\r\n                    <\/tr>\r\n                    <tr>\r\n                        <td>NS2-5FD<\/td>\r\n                    <\/tr>\r\n                    <tr>\r\n                        <td>NS2-5FC\u3001NS2-10FC<\/td>\r\n                    <\/tr>\r\n                    <tr>\r\n                        <td>NS2-10GT1\u3001NS2-20G<\/td>\r\n                    <\/tr>\r\n                <\/tbody>\r\n            <\/table>\r\n        <\/div>\r\n\r\n        <a href=\"https:\/\/www.shi-ftec.co.jp\/en\/services\/\" class=\"btn btn-secondary\">back<\/a>\r\n\r\n    <\/div>\r\n<\/div>","protected":false},"excerpt":{"rendered":"Proposals for preventive maintenance: CNC Precision Surface Grinding Machine &#8211; KSH Series Self-diagnosis: Precision Surface Grinding Machine KSH Series self-diagnosis menu Every part of the machine is a consumable, so it may degrade and be damaged. Using the machine under such circumstances may cause it to break down. To prevent machine breakdowns, use the self-diagnosis menu to determine if it is necessary to replace or repair parts. Inspection items Spindle Hydrostatic bearing spindle Bed bellows Column bed bellows Linear guides Table drive unit If any of the following applies, a machine overhaul may be necessary. First, please check each of the following items. \u2460Spindle The operation time has exceeded 10,000 [&#8230;]<p class=\"text-right\"><a class=\"btn btn-secondary understrap-read-more-link\" href=\"https:\/\/www.shi-ftec.co.jp\/en\/services\/detail1\/\">Read More<\/a><\/p>","protected":false},"author":1,"featured_media":0,"parent":1270,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/empty.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-2149","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.shi-ftec.co.jp\/en\/wp-json\/wp\/v2\/pages\/2149","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.shi-ftec.co.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.shi-ftec.co.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.shi-ftec.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.shi-ftec.co.jp\/en\/wp-json\/wp\/v2\/comments?post=2149"}],"version-history":[{"count":0,"href":"https:\/\/www.shi-ftec.co.jp\/en\/wp-json\/wp\/v2\/pages\/2149\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.shi-ftec.co.jp\/en\/wp-json\/wp\/v2\/pages\/1270"}],"wp:attachment":[{"href":"https:\/\/www.shi-ftec.co.jp\/en\/wp-json\/wp\/v2\/media?parent=2149"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}